■ This product is an advanced intelligent simulation nursing
simulation patient. It is a standardized patient simulation system with
strong physiological driving ability that integrates teaching, training
and assessment. The system can carry out situational teaching according
to the real clinical environment and effectively evaluate the nursing
care of students. Clinical thinking and personal operation skills can
greatly improve students' teamwork spirit.
■ The system is composed
of an adult simulated patient, computer and simulated monitor. Wireless
connection or wired connection can be realized between the simulated
patient, computer and simulated monitor. The simulated patient's weight
is consistent with that of ordinary people, which is conducive to the
systematic learning of students. Able to observe simulated human and
recognize most vital signs. It can realize the direct interaction with
the simulated person and view the status of the simulated patient on the
simulated monitor.
Head and neck
■
The head is completely simulated, the material is soft and the feel is
real; the anatomical structure of the mouth, airway and esophagus is
complete; there are real hair planted, which can be customized for
different genders.
■ The eyes can blink automatically, there are
three speed modes of slow, normal and fast, which can be adjusted; the
state of the eyes can also be adjusted, there are three state modes of
open, closed and half-open; the pupil can be enlarged, reduced or the
eyes are not synchronized; The pupil has the function of light reflex,
which can be adjusted synchronously or asynchronously; normal and slow
reaction speed can be adjusted in response to light; it can
automatically simulate the unequal pupil size under nerve damage; the
eye activity function can be sensed through The device transmits data to
the log; the eye function does not make any noise during operation.
Airway features
■
Airway management: realistic mouth, nose, tongue, gums, pharynx,
esophagus, epiglottis, simulated removal of foreign bodies in the
respiratory tract, and support for opening the airway in three ways:
head-up and neck-lifting, head-up chin-lifting, and hands-jaw-lifting.
Controlled manual or automatic airway opening/closing. The airway can be
opened only when the forehead rest/jaw push-up is correct (it will be
automatically sensed and recorded in the log).
■ The negative
pressure suction device used in clinical use can be used for suction:
oropharyngeal suction, nasopharyngeal suction, suction through tracheal
intubation, and suction through tracheotomy can be performed
respectively.
■ Endotracheal intubation can be performed, which will
be automatically sensed and recorded in the log; oropharyngeal
ventilation, nasopharyngeal ventilation intubation, laryngeal mask
ventilation; fiberoptic bronchoscopy intubation; retrograde intubation;
video laryngoscope tracheal intubation.
■ It can perform
mouth-to-mouth artificial respiration, and can be used in conjunction
with a balloon mask. The size of the blowing volume and the blowing
speed can be displayed, recorded and evaluated in real time. Tracheal
ventilation can be performed.
■ Left and right bronchial ventilation can be performed, which will be automatically sensed and recorded in the log.
■ Can produce flatulence.
■ The patient simulator can be configured to present various difficult airways:
﹡Tongue edema (3 degrees of swelling) ﹡Pharyngeal enlargement ﹡Laryngeal spasm ﹡Trismus ﹡Neck stiffness, etc.
■ Monitoring of correct head position.
■ The function of "cannot be intubated/can be ventilated" can be selected.
■ The function of "cannot be intubated/cannot be ventilated" can be selected.
■
Can perform nasogastric intubation, gastrointestinal decompression and
gastric lavage (will be automatically sensed and recorded in the log).
■ Can perform cricothyroid puncture and tracheotomy training
■
Simulated voice: verbal communication can be realized between the
operator and the simulated person (equipped with a wireless
communication device); the patient's voice can be imitated through the
system preset or user-defined voice file (reproduce the patient's
groaning, coughing, and vomiting sounds). Wait).
■ The system has a
built-in simulated secretion storage device, and the software has a
secretion control platform, which can realistically simulate sweat,
tears, saliva, foaming at the mouth, etc., so that it can automatically
change from the simulated person's forehead, the corners of the eyes,
and the corners of the mouth according to the changing conditions. ,
ears, nose, etc. Forehead sweat can show through inconspicuous pores.
■ Can simulate carotid pulse.
■ It can simulate cyanosis of the lips, and the severity of cyanosis is related to blood oxygen saturation.
Chest and abdomen
■ Obvious signs on the chest surface (sternal angle, xiphoid process, ribs, etc.) are beneficial to clinical operations.
■
It can realize spontaneous breathing, and the chest rises and falls
when breathing. Various breathing modes can be set, unilateral or
bilateral chest ups and downs can be simulated, the breathing rate can
be adjusted.
■ It can simulate normal or abnormal breath sounds; it can simulate unilateral and lobar breath sounds.
■ When using the mask for ventilation, the ventilation volume will be displayed on the computer screen.
■
There are 5 heart sound auscultation areas, 5 lung sound auscultation
areas and 4 abdominal auscultation areas in front of the simulated
patient's body.
■ There are 6 auscultation areas behind the simulated patient's body.
■
Abdominal palpation can be performed. According to the needs of the
disease, the abdominal pain site can be set in the medical record
editing. When the abdomen is palpated, the patient will feel pain,
accompanied by a moaning sound. , and corresponding display on the
software.
■ It can simulate the function of flatulence.
■ Pleural puncture and placement of chest drains can be performed on both sides.
■ Sternal bone marrow puncture.
■
Built-in bleeding control system, which can simulate bleeding in many
parts of the body, and can adjust the amount and speed of bleeding
according to the location and size of the wound. The vital signs can
automatically change with the severity of blood loss and treatment.
■
Catheterization function: catheterization training can be performed,
and the urine volume can be automatically adjusted with the change of
the condition; the system can control the urine output and the flow rate
can be adjusted. Male and female genitalia are interchangeable.
■ Enema operation can be performed, and the operation record is displayed in the log.
■ CPR training implementation standard: 2020 American Heart Association Guidelines for CPR and Cardiovascular First Aid.
﹡Press to automatically generate pulse, blood pressure waveform and electrocardiogram.
﹡Real compression depth; it can provide immediate feedback on the
quality of CPR, including compression depth, compression frequency,
compression position information, whether the compression rebound is
complete, ventilation tidal volume, ventilation frequency, etc.
Graphical and text interface. Real-time feedback on the quality of
cardiopulmonary resuscitation. It can display the situation of pressing
and rebounding.
■ More than 100 kinds of electrocardiograms, vital
signs can be changed automatically with the changes of heart waves and
treatment.
■ The ECG waveform, basal heart rhythm and premature contraction can be adjusted arbitrarily.
■
The 12-lead ECG can be displayed on the monitor in real time, in line
with the changes in vital signs. There is a separate icon on the monitor
that, when clicked, displays a twelve-lead ECG.
■ Real electrical
defibrillation and electrical cardioversion: Defibrillation and
electrical cardioversion can be performed with real clinical
defibrillators. The defibrillation effect and pacing threshold can be
set and automatically displayed according to the needs of treatment and
situation. After various treatments, the corresponding symptoms, signs
and monitoring parameters of the simulated person will automatically
change in accordance with the condition at that time. An optional analog
defibrillator is also available (energy will be transmitted to the
simulator during defibrillation, and the software has defibrillation
records).
limbs
■
Non-invasive blood pressure measurement can be performed with a
cuff-type sphygmomanometer and a monitor. The cuff-type sphygmomanometer
needs to manually measure the blood pressure by auscultation of
Korotkov sound, the volume can be adjusted, and the blood pressure
reading must be consistent with the condition at the time.
■ When
measuring blood pressure, it can automatically detect and record whether
it touches the brachial artery, can automatically detect the cuff
binding position (upper, correct, lower), and detect the drop speed of
the mercury column or the drop value of the pressure gauge in real time
(operation record). displayed in the log).
■ Can perform
venipuncture training on the back of the hand and the arm, including the
precious vein, median vein, and cephalic vein.
■ There is a sense
of failure during puncture, and blood can be returned after correct
puncture, and exercises such as infusion can be performed.
■ The
pulse of carotid artery, femoral artery, brachial artery, radial artery,
dorsal pedis artery, popliteal artery and posterior tibial artery can
be palpated and automatically synchronized with electrocardiogram. The
pulse will vary with the condition and with the treatment. Palpation
pulses are automatically sensed and recorded. Pulse intensity varies
with blood pressure.
■ Tibial bone marrow puncture, the puncture is
correct, the fluid can be extracted, and the tibial puncture module can
be replaced.。
■ It can simulate the convulsion of the left hand, and the convulsion can be adjusted in intensity.
■
Peripheral fingers and toes can simulate four different degrees of
cyanosis, and the severity of cyanosis is related to blood oxygen
saturation.
Features of the software
■
The simulator operating software can run, control and monitor all
aspects of learning, and can operate in medical record mode and special
mode.
■ Ase mode: With a case editing platform, the operator can
develop cases arbitrarily, all changes of the simulator can be
pre-designed, and the preset modules, time and process of the patient's
physiological and pathological reactions to drugs and treatments can be
easily selected during design. are controllable.
■ The running case can be paused, fast forwarded and saved.
■
Evaluation report: including case simulation details, operation log,
CPR report, and comments. The evaluation report system can be stored and
printed, and can also be used as a basis for dynamic teaching and
assessment.
■ Individual training: training in clinical emergency
diagnosis thinking, defibrillation, auscultation of heart and lung
sounds, catheterization, CPR and tracheal intubation.