■ The upper torso simulator of an adult male is made of polymer
material, which is environmentally friendly and pollution-free; The
anatomical landmarks are obvious and can touch the nipples, ribs,
sternum, and xiphoid process, making it easy to operate and locate.
■ The
anatomical position of the head and neck of the simulator is accurate,
and the head can swing left and right with a horizontal rotation of 180
degrees, making it easy to remove oral foreign objects, and the
mandibular joint can move.
■ Pupil teaching: One side of the pupil is dilated and the other side is normal.
■ Palpable carotid artery pulsation.
■ Implementation
standards for cardiopulmonary resuscitation: 2020 American Heart
Association Guidelines for Cardiopulmonary Resuscitation and
Cardiovascular Emergency; There are three feasible methods to open the
airway: lifting the chin, neck, and jaw with both hands; When the
simulator does not have an open airway, the airway is closed and only
when it is open can air be blown in; Oral to oral artificial respiration
or the use of a simple respirator to assist breathing, effective
artificial respiration can reveal chest undulations.
■ Having a real mouth, teeth, epiglottis, and uvula, it is possible to perform tracheal intubation.
■ In training
mode, the electronic display can monitor the pressing depth, pressing
position, pressing frequency, blowing time, and tidal volume in real
time, and can perform data statistics such as pressing correctly,
pressing incorrectly, pressing frequency, blowing time, blowing
correctly, and blowing incorrectly.
■ The depth of pressing and the
moisture level have light bars displaying yellow too small, green
correctly, and red too large. The electronic display can display the
correct pressing position, upward, downward, leftward, and rightward
through indicator lights. When excessive gas is blown into the stomach,
there is an indicator light prompt, and all operations are accompanied
by voice prompts.
■ In the assessment mode, perform chest
compressions and artificial respiration according to the latest standard
30:2 ratio. The electronic display can monitor the pressing depth,
pressing position, pressing frequency, blowing time, and moisture level
in real time, and can perform data statistics such as correct pressing,
incorrect pressing, pressing frequency, excessive pressing, insufficient
pressing, blowing time, correct blowing, blowing error, excessive
blowing, and insufficient blowing. The pressure depth and moisture level
have light bars displaying yellow too small, green correctly, and red
too large. The electronic display can display the correct pressing
position, upward, downward, leftward, and rightward through indicator
lights. When excessive gas is blown into the stomach, there will be
indicator lights indicating.
■ Equipped with CPR specific operation cushion, with a thickness of 8mm, convenient for practice and assessment.