■ The simulated human is made of polymer materials, which are
environmentally friendly and pollution-free; The anatomical landmarks
are obvious and can touch the nipples, ribs, sternum, and xiphoid
process, making it easy to operate and locate.
■ Simulate the
accurate anatomical position of the human head and neck, with the head
able to swing left and right and rotate horizontally 180 degrees, making
it easy to remove oral foreign objects.
■ The eyeball adopts OLED
simulation, with visible colored retina, black pupils, transparent
crystals, and the ability to reflect light at any angle; In a dead
state, the pupil dilates and the reflex to light disappears.
■ The carotid artery pulsation can be palpable, and in a state of death, the carotid artery pulsation disappears.
■
Cardiopulmonary resuscitation, execution standard: 2020 American Heart
Association Cardiopulmonary Resuscitation and Cardiovascular Emergency
Guidelines, supine position with head tilted back.
* Feasible chest compressions.
* There are three feasible methods to open the airway: lifting the chin, neck, and jaw with both hands.
*
It is feasible to perform mouth to mouth artificial respiration or use a
simple respirator to assist breathing, and effective artificial
respiration can show chest undulations.
■ The latest bidirectional wave defibrillation technology can be used for real defibrillation.
■ endotracheal intubation
■
There are two communication methods to choose between analog humans and
computers: USB communication and wireless WIFI communication.
■ The
first aid chain has multiple automatic reactions throughout the entire
process, including tapping, assessing carotid artery awareness, opening
the airway, gas entering the stomach, CPR, and other indicators.
■ Electronic monitoring of multiple indicators throughout the process:
*
Pressing section: Monitor the number of presses (multiple or few),
pressing position (correct or incorrect), pressing depth (too large or
too small), pressing frequency (correct or incorrect), pressing rebound,
and displaying the interruption time of pressing
* Pressing
operation waveform display: Real time display of pressing operation
waveform, which can determine pressing depth, pressing frequency,
pressing rebound situation, pressing interruption time, pressing
position, etc.
* Monitoring of Blowing Part: Blowing frequency
(excessive or insufficient), tidal volume (excessive or insufficient),
tidal time, and gas intake into the stomach.
* Blowing operation
waveform display: Real time display of blowing operation waveform,
through which the blowing volume, blowing cycle, and moisture time can
be determined.
■ According to the operating standards of the 2020
American Heart Association Guidelines for Cardiopulmonary Resuscitation
and Cardiovascular First Aid, cardiopulmonary resuscitation operations
can be evaluated, and the operation meets the standards, simulating
human resurrection; The operation did not meet the standards, resulting
in simulated human death.
■ The transcript can be saved and printed, and can be connected to a universal printer for printing.
■
CPR simulation training, with three operating modes: practice,
assessment, and actual combat. Each mode can set its own training time,
CPR cycle times, etc.
■ Full course electrocardiogram display:
*
Before rescue: An electrocardiogram showing imminent death,
disappearance of respiratory chart, and blood pressure below 60mmHg.
*
Rescue in progress: During the pressing operation, the pressing
electrocardiogram is displayed with the same frequency as the pressing
frequency, and the respiratory monitoring displays the tidal operation
graph.
* After successful rescue: it shows sinus rhythm and breathing returns to normal.