■ Adult simulator, with obvious signs on the body surface, made of high-molecular environmental protection materials. The simulated body position is the correct lumbar puncture and the arched lying position for epidural anesthesia puncture.
■ Functional requirements are that the following operations are possible: subarachnoid anesthesia (spinal anesthesia), lumbar puncture for cerebrospinal fluid pressure measurement, collection of cerebrospinal fluid samples, epidural block anesthesia, coccygeal nerve block, caudal nerve block, Lumbar sympathetic nerve block.
■ Diagnostic puncture of the lumbar spine can be performed.
■ Therapeutic puncture of the lumbar spine can be performed: drugs can be injected, an appropriate amount of cerebrospinal fluid can be taken, and bloody cerebrospinal fluid can be drained.
■ The same puncture site can be practiced repeatedly.
■ Automatic circulation of cerebrospinal fluid.
■ Cerebrospinal fluid pressure can be adjusted according to teaching or assessment needs.
■ Electronic automatic monitoring of needle insertion site, deviation from needle insertion site, automatic voice alarm: puncture site error! When the needle position is correct, there is also a voice prompt, and training mode and assessment mode can be set. There is no voice prompt in assessment mode.