Children CPR simulator (Tablet)

Consult
Detail intruduction

■  The simulated human is made of polymer materials, which are environmentally friendly and pollution-free; The anatomical landmarks are obvious and can touch the nipples, ribs, sternum, and xiphoid process, making it easy to operate and locate.
■  Simulate the accurate anatomical position of the human head and neck, with the head able to swing left and right and rotate horizontally 180 degrees, making it easy to remove oral foreign objects.
■  The eyeball adopts OLED simulation, with visible colored retina, black pupils, transparent crystals, and the ability to reflect light at any angle;  In a dead state, the pupil dilates and the reflex to light disappears.
■  The carotid artery pulsation can be palpable, and in a state of death, the carotid artery pulsation disappears.
■  There are three feasible methods to open the airway: lifting the chin, neck, and jaw with both hands.
■  It is feasible to perform mouth to mouth artificial respiration or use a simple respirator to assist breathing, and effective artificial respiration can show chest undulations.

1724297566554231.png

Electronic monitoring of multiple indicators throughout the process:
* Pressing section: Monitor the number of presses (excessive or insufficient), pressing position (correct or incorrect), pressing depth (too large or too small), pressing frequency (correct or incorrect), pressing rebound, and displaying pressing interruption time.
* Monitoring of Blowing Part: Blowing frequency (excessive or insufficient), tidal volume (excessive or insufficient), tidal time, and gas intake into the stomach.
■  Real time display of parameters such as pressing depth, pressing position, pressing frequency, tidal volume, tidal time, airway opening, and gas intake throughout the entire process.
■  Tablets can be connected by scanning a QR code or manually selecting a Bluetooth name for wireless connection. Different connection methods and functions can be configured by scanning an activation code, as well as whether to defibrillate and use a portable Bluetooth printer to print transcripts.
■  The system is divided into four operation modes: specialized training, comprehensive training, comprehensive assessment, and practical assessment. Waveform charts and bar charts are used to display the depth and tidal volume of each press, and the frequency of each press is recorded in a marked point manner to visually display the specific situation of each press and blowing.
* Operational evaluation criteria: comply with AHA operating procedures: assess environmental safety, pat and call, assess breathing and carotid artery, call for help, open airway, remove oral foreign objects, and use AED.
* Operation time limit, compression ventilation ratio, CPR cycle number, tidal volume range, tidal compliance rate, compression depth range, compression compliance rate, and other settings.
* Operation statistics: Determine environmental safety, pat and call, determine breathing and carotid artery, call for help, open airway, remove oral foreign objects, AED use, correct blowing rate, number of blowing errors, analysis of blowing errors (too large, too small, too much, too little), correct pressing rate, number of pressing errors, analysis of pressing errors (too large, too small, too much, too little, wrong position, incomplete rebound of pressing), incorrect pressing frequency, and too large pressing interval.
■  Full course electrocardiogram display:
* Before rescue: ECG showing imminent death, disappearance of respiratory chart, and blood pressure below 60mmHg
* During rescue: When performing compression operations, display the compression electrocardiogram with a frequency consistent with the compression frequency, and respiratory monitoring displays the tidal operation graph
* After successful rescue: it shows sinus rhythm and breathing returns to normal.