■ Simulate artificial polymer materials, environmentally friendly and pollution-free; The anatomical landmarks are obvious and can touch the nipples, ribs, sternum, and xiphoid process, making it easy to operate and locate.
■ Simulate the accurate anatomical position of the human head and neck, with the head able to swing left and right and rotate horizontally 180 degrees, making it easy to remove oral foreign objects.
■ The eyeball adopts OLED simulation, with visible colored retina, black pupils, transparent crystals, and the ability to reflect light at any angle; The pupil has a reflex to light, which automatically changes with the condition. In a dead state, the pupil dilates and the reflex to light disappears.
■ The carotid artery pulsation can be palpable, and in a state of death, the carotid artery pulsation disappears; The intensity of carotid artery pulsation has force feedback, and the greater the pressure on the finger, the stronger the pulse beating, which can be perceived as whether there is a checked pulse.
■ The head is equipped with sensors, and the open airway can automatically provide feedback
■ The emergency chain has multiple automatic responses throughout the entire process, including airway opening, gas entry into the stomach, CPR, and other indicators.
■ There are three feasible methods to open the airway: lifting the chin, neck, and jaw with both hands
■ It is feasible to perform mouth to mouth artificial respiration or use a simple respirator to assist breathing, and effective artificial respiration can show chest undulations
■ There are two communication methods to choose between analog humans and computers: USB communication and wireless WIFI communication.
■ Electronic monitoring of multiple indicators throughout the process:
* Pressing section: Monitor the number of presses (multiple or few), pressing position (correct or incorrect), pressing depth (too large or too small), pressing frequency (correct or incorrect), pressing rebound, and displaying the interruption time of pressing
* Pressing operation waveform display: Real time display of pressing operation waveform, through which pressing depth, pressing frequency, pressing rebound situation, pressing interruption time, pressing position, etc. can be determined
* Monitoring of Blowing Part: Blowing frequency (excessive or insufficient), tidal volume (excessive or insufficient), tidal time, and gas intake into the stomach
* Blowing operation waveform display: Real time display of blowing operation waveform, through which the blowing volume, blowing cycle, and moisture time can be determined
■ Cardiopulmonary resuscitation operations can be evaluated, and the operation meets the standards, simulating human resurrection; The operation did not meet the standards, resulting in simulated human death.
■ The transcript can be saved and printed, and can be connected to a universal printer for printing.
■ CPR simulation training: There are two operating modes, practice, assessment, and each mode can set its own training time, CPR cycle number, etc
* Practice mode CPR, with specialized exercises available for pressing depth, pressing frequency, blowing, etc.
* The pressing frequency has a guiding prompt sound of 110 times per minute, and there are prompts for excessive or insufficient pressing. Blowing too much, too little, and the sound of gas entering the stomach.
* Candidate Information: The operation time, candidate number, name, and operation time can also be recorded.