SY/E203

Advanced Infant CPR System -Ricky

Consult
Detail intruduction

■  The baby is a whole person, with obvious anatomical landmarks: xiphoid process, sternum, nipple, etc., which is convenient for operation and positioning
■  Execution standard: "2020 American Heart Association Guidelines for Cardiopulmonary Resuscitation and Cardiovascular First Aid"
■  There is pupil light reflex, and the pupil changes automatically with the change of the condition. In the state of death, the pupil is dilated, the light reflex disappears, the first aid is successful, and the pupil returns to normal, with direct light reflex and indirect light reflex.
■  Brachial artery pulsation can be palpated. In the state of death, the brachial artery pulsation disappears, the first aid is successful, and the brachial artery pulsation resumes.
■  The manikin has physiological signs: in death state, there is cyanosis of the lips, the first aid is successful, the cyanosis disappears, and the baby cries automatically.
■  Wireless WIFI communication is used between the simulator and the computer.
■  It can perform real defibrillation (simulated defibrillator is optional), and the software will display the corresponding joule amount during defibrillation.

1724293500765588.png

■  Cardiopulmonary resuscitation: supine position, head can be tilted back to facilitate removal of foreign bodies in the respiratory tract
   *  Three methods of raising the head and raising the chin, raising the head and raising the neck, and raising the jaw with both hands can be used to open the airway
   *  It is possible to perform mouth-to-mouth artificial respiration or use a simple respirator to assist breathing. Effective artificial respiration can see thoracic rise and fall
   *  The whole process of electronic monitoring of multiple indicators:
   *  Pressing part
   * Monitor the number of presses (press more, press less), press position (correct, incorrect), press depth (too large, too small), press frequency (correct, incorrect), press rebound, press interruption time display
   * Press operation waveform display
   * Real-time display of the pressing operation waveform, which can determine the pressing depth, pressing frequency, pressing rebound, pressing interruption time, pressing position, etc.
   * Air blowing part
   * Monitor the number of blows (more blows, less blows), tidal volume (too large, too small), tidal time, and gas into the stomach
   *  Waveform display of blowing operation
   *  Real-time display of the blowing operation waveform, the blowing volume, blowing cycle and tidal time can be judged by the waveform
■  Cardiopulmonary resuscitation has three operation modes: practice, assessment and actual combat, and you can set the training time and the number of CPR cycles by yourself. Real-time display of compression depth and tidal volume in histogram and waveform, making the compression and blowing situation more vivid.
   *  In the training mode, special exercises such as pressing, pressing frequency, blowing, and defibrillation can be performed.
   *  The pressing frequency has a guide tone of 110 times/min, and the pressing has too large or too small tone. Insufflation is too large, too small, gas into the stomach prompt sound.