■ The baby is a whole person, with obvious anatomical landmarks:
xiphoid process, sternum, nipple, etc., which is convenient for
operation and positioning
■ Execution standard: "2020 American Heart
Association Guidelines for Cardiopulmonary Resuscitation and
Cardiovascular First Aid"
■ There is pupil light reflex, and the
pupil changes automatically with the change of the condition. In the
state of death, the pupil is dilated, the light reflex disappears, the
first aid is successful, and the pupil returns to normal, with direct
light reflex and indirect light reflex.
■ Brachial artery pulsation
can be palpated. In the state of death, the brachial artery pulsation
disappears, the first aid is successful, and the brachial artery
pulsation resumes.
■ The manikin has physiological signs: in death
state, there is cyanosis of the lips, the first aid is successful, the
cyanosis disappears, and the baby cries automatically.
■ Wireless WIFI communication is used between the simulator and the computer.
■
Cardiopulmonary resuscitation: supine position, head can be tilted back
to facilitate removal of foreign bodies in the respiratory tract
* Three methods of raising the head and raising the chin, raising the
head and raising the neck, and raising the jaw with both hands can be
used to open the airway
* It is possible to perform
mouth-to-mouth artificial respiration or use a simple respirator to
assist breathing. Effective artificial respiration can see thoracic rise
and fall
* The whole process of electronic monitoring of multiple indicators:
* Pressing part
* Monitor the number of presses (press more, press less), press
position (correct, incorrect), press depth (too large, too small), press
frequency (correct, incorrect), press rebound, press interruption time
display
* Press operation waveform display
* Real-time
display of the pressing operation waveform, which can determine the
pressing depth, pressing frequency, pressing rebound, pressing
interruption time, pressing position, etc.
* Air blowing part
* Monitor the number of blows (more blows, less blows), tidal volume
(too large, too small), tidal time, and gas into the stomach
* Waveform display of blowing operation
* Real-time display of the blowing operation waveform, the blowing
volume, blowing cycle and tidal time can be judged by the waveform
■
Cardiopulmonary resuscitation has three operation modes: practice,
assessment and actual combat, and you can set the training time and the
number of CPR cycles by yourself. Real-time display of compression depth
and tidal volume in histogram and waveform, making the compression and
blowing situation more vivid.
* In the training mode, special
exercises such as pressing, pressing frequency, blowing, and
defibrillation can be performed.
* The pressing frequency has a
guide tone of 110 times/min, and the pressing has too large or too small
tone. Insufflation is too large, too small, gas into the stomach prompt
sound.